You are here: Monitoring tools > Monitoring event messages > Event messages

Event messages

The following table identifies the Double-Take events. The event ID is followed by the event message. Below the ID and message you will find the following information.

 

1:   This evaluation period has expired. Mirroring and replication have been stopped. To obtain a license, please contact your vendor.

Event log—Application

Source—Double-Take

Category—ActivationKey

Type or Level—Error

Required response—Contact your vendor to purchase either a single or site license.

SCOM alert—Enabled

2:   The evaluation period expires in %1 day(s).

Event log—Application

Source—Double-Take

Category—ActivationKey

Type or Level—Information

User action required—Contact your vendor before the evaluation period expires to purchase either a single or site license.

SCOM alert—Enabled

3:   The evaluation period has been activated and expires in %1 day(s).

Event log—Application

Source—Double-Take

Category—ActivationKey

Type or Level—Information

User action required—Contact your vendor before the evaluation period expires to purchase either a single or site license.

SCOM alert—Disabled

4:   Duplicate activation codes detected on machine %1 from machine %2.

Event log—Application

Source—Double-Take

Category—ActivationKey

Type or Level—Warning

User action required—If you have an evaluation license or a site license, no action is necessary. If you have a single license, you must purchase either another single license or a site license.

SCOM alert—Enabled

5:   This product edition can only be run on Windows Server or Advanced Server running the Server Appliance Kit.

Event log—Application

Source—Double-Take

Category—ActivationKey

Type or Level—Error

User action required—Verify your activation code has been entered correctly and contact technical support.

SCOM alert—Enabled

200:   ExchFailover failover from %1 to %2 was started in commit mode. See log file %3 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Information

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

201:   ExchFailover failover from %1 to %2 was started in test mode. See log file %3 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Information

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

202:   ExchFailover failback to %1 from %2 was started in commit mode. See log file %3 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Information

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

203:   ExchFailover failback to %1 from %2 was started in test mode. See log file %3 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Information

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

204:   ExchFailover setup started for server %1. See log file %2 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Information

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

205:   ExchFailover was unable to open the default log file. A new log file has been created. All messages will be log in %1.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Error

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

210:   ExchFailover completed. Moved %1 users in %2 mail stores in %3 seconds. Check log file %4 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Success

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

211:   ExchFailover completed with warnings. Moved %1 users in %2 mail stores in %3 seconds. Check log file %4 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Warning

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

212:   ExchFailover completed. Tested %1 users in %2 mail stores in %3 seconds. Check log file %4 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Success

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

213:   ExchFailover completed with warnings. Moved %1 users in %2 mail stores in %3 seconds. Check log file %4 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Warning

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

214:   ExchFailover setup completed. Updated %1 mail stores in %2 seconds. Check log file %3 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Success

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

220:   ExchFailover start failed. Could not open log file: %1.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Error

User action required—Restart failover. Contact technical support if this event occurs again.

SCOM alert—No rule defined

221:   ExchFailover start failed. Invalid command line arguments. See log file %1 for details.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Error

User action required—See the specific log message for additional details.

SCOM alert—No rule defined

222:   ExchFailover start failed. Double-Take is not licensed on this machine.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Error

User action required—Verify your activation code has been entered correctly and contact technical support.

SCOM alert—No rule defined

223:   ExchFailover start failed due to an Active Directory error.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Error

User action required—Restart failover. Contact technical support if this event occurs again.

SCOM alert—No rule defined

224:   ExchFailover failed to find one (or both) of the Exchange servers. Check the server names. This can also occur if the process does not have sufficient privileges to access Active Directory.

Event log—Application

Source—ExchFailover

Category—None

Type or Level—Error

User action required—Verify the Exchange server names and the account has sufficient privileges to update Active Directory.

SCOM alert—No rule defined

1000:   An exception occurred: %1

Event log—Application

Source—DTCounters

Category—None

Type or Level—Error

User action required—Run the installation and select Repair. Contact technical support if this event occurs again.

SCOM alert—Enabled

1001:   The Double-Take counter DLL could not initialize the statistics handler object to gather performance data.

Event log—Application

Source—DTCounters

Category—None

Type or Level—Error

User action required—Run the installation and select Repair. Contact technical support if this event occurs again.

SCOM alert—Enabled

1002:   The Double-Take counter DLL could not map shared memory file containing the performance data.

Event log—Application

Source—DTCounters

Category—None

Type or Level—Error

User action required—Run the installation and select Repair. Contact technical support if this event occurs again.

SCOM alert—Enabled

1003:   The Double-Take counter DLL could not open the "Performance" key in the Double-Take section of the registry.

Event log—Application

Source—DTCounters

Category—None

Type or Level—Error

User action required—Run the installation and select Repair. Contact technical support if this event occurs again.

SCOM alert—Enabled

1004:   The Double-Take counter DLL could not read the "First Counter" value under the Double-Take\Performance Key.

Event log—Application

Source—DTCounters

Category—None

Type or Level—Error

User action required—Run the installation and select Repair. Contact technical support if this event occurs again.

SCOM alert—Enabled

1005:   The Double-Take counter DLL read the "First Help" value under the Double-Take\Performance Key.

Event log—Application

Source—DTCounters

Category—None

Type or Level—Error

User action required—Run the installation and select Repair. Contact technical support if this event occurs again.

SCOM alert—Enabled

1006:   The Double-Take counter DLL could not create event handler for the worker thread.

Event log—Application

Source—DTCounters

Category—None

Type or Level—Error

User action required—Run the installation and select Repair. Contact technical support if this event occurs again.

SCOM alert—Enabled

3000:   Logger service was successfully started.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

3001:   Logger service was successfully stopped.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4000:   Kernel was successfully started.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4001:   Target service was successfully started.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4002:   Source service was successfully started.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4003:   Source service was successfully stopped.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4004:   Target service was successfully stopped.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4005:   Kernel was successfully stopped.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4006:   Service has aborted due to the following unrecoverable error: %1

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Restart the Double-Take service.

SCOM alert—Enabled

4007:   Auto-disconnecting from %1 (%2) for Replication Set %3, ID: %4 due to %5

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—The connection is auto-disconnecting because the disk-based queue on the source has been filled, the service has encountered an unknown file ID, the target server has restarted, or an error has occurred during disk queuing on the source or target (for example, Double-Take cannot read from or write to the transaction log file).

SCOM alert—Enabled

4008:   Auto-disconnect has succeeded for %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4009:   Auto-reconnecting Replication Set %1 to %2 (%3)

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4010:   Auto-reconnect has succeeded connecting Replication Set %1 to %2 (%3)

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4011:   Auto-reconnect has failed connecting Replication Set %1 to %2 (%3)

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Manually reestablish the job to target connection.

SCOM alert—Enabled

4012:   %1

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—This is a placeholder message for many other messages. See the specific log message for additional details.

SCOM alert—Enabled

4013:   %1

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—This is a placeholder message for many other messages. See the specific log message for additional details.

SCOM alert—Enabled

4014:   Service has started network transmission.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4015:   Service has stopped network transmission.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4016:   Service has established a connection to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4017:   Service has disconnected from %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4018:   %1, however, mirroring and replication have been disabled as a restore is required due to a previous failover.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Perform a restoration.

SCOM alert—Enabled

4019:   Service has started a mirror to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4020:   Service has paused a mirror to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4021:   Service has resumed a mirror to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4022:   Service has stopped a mirror to %1 for Replication Set %2, ID: %3, %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4023:   Service has completed a mirror to %1 %2 for Replication Set %3, ID: %4, %5

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4024:   Service has started Replication to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4025:   Service has stopped Replication to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4026:   The target has been paused due to user intervention.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4027:   The target has been resumed due to user intervention.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4028:   Registration of service class with Active Directory failed. Verify that the Active Directory server is up and the service has the proper permissions to update its entries.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Verify that the Active Directory server is running and that the Double-Take service has permission to update Active Directory.

SCOM alert—Enabled

4029:   Registration of service instance with Active Directory failed. Verify that the Active Directory server is up and the service has the proper permissions to update its entries.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Verify that the Active Directory server is running and that the Double-Take service has permission to update Active Directory.

SCOM alert—Enabled

4030:   RSResource.dll has an unknown error. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4031:   RSResource.dll could not be opened. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4032:   The RSResource.dll component version does not match the component version expected by the product. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4033:   RSResource.dll build version is invalid. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4034:   Error verifying the service name. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4035:   Error verifying the product name. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4036:   Error verifying the vendor name. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4037:   Error verifying the vendor URL name. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4038:   Error verifying the product code. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4039:   Error while reading RSResource.dll. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4040:   The product code is illegal for this computer hardware. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4041:   The product code is illegal for this operating system version. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4042:   The product code requires installing the Windows Server Appliance Kit. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4043:   This product can only be run on a limited number of processors and this server exceeds the limit. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reinstall the software, using the installation Repair option, to install a new copy of the RSResource.dll. Contact technical support if this error persists.

SCOM alert—Enabled

4044:   An error was encountered and replication has been stopped. It is necessary to stop and restart the service to correct this error.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Contact technical support if this error persists.

SCOM alert—Enabled

4045:   %1 value must be between 1025 and 65535. Using default of %2.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Verify that the Double-Take port value you are trying to use is within the valid range. If it is not, it will automatically be reset to the default value.

SCOM alert—Enabled

4046:   This service failed to start because of a possible port conflict. Win32 error: %1

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Verify that the Double-Take ports are not conflicting with ports used by other applications.

SCOM alert—Enabled

4047:   Could not load ZLIB DLL %1. Some levels of compression will not be available.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—The compression levels available depend on your operating system. You can reinstall the software, using the installation Repair option, to install a new copy of the DynaZip.dll, or contact technical support if this error persists.

SCOM alert—Enabled

4048:   Service has started a delete orphans task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4049:   Service has paused a delete orphans task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4050:   Service has resumed a delete orphans task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4051:   Service has stopped a delete orphans task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4052:   Service has completed a delete orphans task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4053:   Service has started a restore task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4054:   Service has paused a restore task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4055:   Service has resumed a restore task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4056:   Service has stopped a restore task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4057:   Service has completed a restore task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4058:   Service has started a verification task to %1 (%2) for Replication Set %3, ID: %4, Checksum: %5

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4059:   Service has paused a verification task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4060:   Service has resumed a verification task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4061:   Service has stopped a verification task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4062:   Service has completed a verification task to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4063:   Bandwidth limit to %1 (%2) has changed to %3.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4064:   Bandwidth limit to %1 (%2) is now in the "%3" period at %4.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4065:   Target data state for connection %1 from %2 (%3) has changed because %4.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—No action required.

SCOM alert—Enabled

4066:   The product code requires a virtual server environment. The product functionality has been disabled.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—The activation code you are using is for the Virtual SystemsTM edition. This code will not work on non-virtual server environments.

SCOM alert—Enabled

4067:   No replication ops have been received from the driver for an extended period of time.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Check other messages for errors with the Double-Take drivers, and correct as required. If there are no driver messages, verify that your drives are connected to the source. If this error persists, contact technical support.

SCOM alert—Enabled

4068:   Failed to write to a replicating volume.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Reboot the source server. Contact technical support if this event occurs again.

SCOM alert—Enabled

4069:   The option MoveOrphansDir has been updated because it was missing or empty.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—No action required.

SCOM alert—Enabled

4070:   An error occurred while reading data for connection %1. All data needs to be remirrored. See the log for details.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Initiate a remirror to guarantee data integrity. Contact technical support if this event occurs repeatedly.

SCOM alert—Enabled

4096:   The registry parameter %2 is unknown.

Event log—System

Source—RepDrv

Category—None

Type or Level—Warning

User action required—Delete the parameter and report this issue to technical support.

SCOM alert—Enabled

4097:   Failed to initialize WMI support. The last Word in the Data Window is the NT status code.

Event log—System

Source—RepDrv, RepKap, RepHsm, or RepSis

Category—None

Type or Level—Warning

User action required—No action required.

SCOM alert—Enabled

4097:   The file system filter failed to load. Replication will not occur. Reboot your server and contact technical support if this error occurs again. The last Word in the Data window is the NT status code.

Event log—System

Source—RepDrv

Category—None

Type or Level—Error

User action required—Reboot your server and contact technical support if this event occurs again.

SCOM alert—Enabled

4098:   The registry parameters failed to load, so the default configuration values will be used. The last Word in the Data window is the NT status code.

Event log—System

Source—RepKap

Category—None

Type or Level—Warning

User action required—No action required.

SCOM alert—Enabled

4098:   The control device %2 was not created. Communication with the service will be disabled. Reboot the server and contact technical support if this error occurs again. The last Word in the Data window is the NT status code.

Event log—System

Source—RepDrv, RepDac, RepKap, or RepHsm

Category—None

Type or Level—Error

User action required—Reboot your server and contact technical support if this event occurs again.

SCOM alert—Enabled

4099:   The driver detected a hard link for a file on drive %2. Hard links are not supported. Changes to this file will not be replicated.

Event log—System

Source—RepDrv

Category—None

Type or Level—Warning

User action required—Hard links are not supported.

SCOM alert—Enabled

4099:   The driver failed to register with filter manager. Reboot the server and contact technical support if this error occurs again. The last Word in the Data window is the NT status code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Reboot your server and contact technical support if this event occurs again.

SCOM alert—Enabled

4100:   Product activation code is invalid. Please check that it is typed correctly and is valid for the version of the operating system in use.

Event log—Application

Source—Double-Take

Category—ActivationKey

Type or Level—Error

User action required—If you are in the process of installing Double-Take, verify that you are using a 24 character alpha-numeric code. If Double-Take is already installed, confirm that the code entered is correct. If the code appears to be correct, contact technical support.

SCOM alert—Enabled

4100:   The versions of the driver and the filter driver do not match. Replication will not occur. Reboot your server. If this error occurs again, reinstall the software. Contact technical support if this error occurs after the software has been reinstalled. The last three Words in the Data window are the NT status code and the driver version numbers.

Event log—System

Source—RepDrv

Category—None

Type or Level—Error

User action required—Reboot your server. Reinstall the software if this event occurs again. Contact technical support if this event occurs after reinstalling the software.

SCOM alert—Enabled

4101:   This service will not run on this device. Contact your sales representative for upgrade procedures.

Event log—Application

Source—Double-Take

Category—ActivationKey

Type or Level—Error

User action required—The activation code does not match the type of server you are attempting to run on. Contact your vendor for a new activation code or contact technical support.

SCOM alert—Enabled

4110:   Target cannot write %1 due to target disk being full. Operation will be retried (%2 times or forever)

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—The disk on the target is full. The operation will be retried according to the TGExecutionRetryLimit setting.

SCOM alert—Enabled

4111:   Target can not write %1 due to a sharing violation. Operation will be retried (%2 times or forever)

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—A sharing violation error is prohibiting Double-Take from writing on the target. The operation will be retried according to the TGExecutionRetryLimit setting.

SCOM alert—Enabled

4112:   Target can not write %1 due to access denied. Operation will be retried (%2 times or forever)

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—An access denied error is prohibiting Double-Take from writing on the target. The operation will be retried according to the TGExecutionRetryLimit setting..

SCOM alert—Enabled

4113:   Target can not write %1 due to an unknown reason. Operation will be retried (%2 times or forever). Please check the log files for further information on the error.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—An unknown error is prohibiting Double-Take from writing on the target. The operation will be retried according to the TGExecutionRetryLimit setting.

SCOM alert—Enabled

4120:   Target write to %1 was completed successfully after %2 retries.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4150:   Target write %1 failed after %2 retries and will be discarded. See the event log or log files for error conditions. After correcting the problem, you should re-mirror or run a verify to resynchronize the changes.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—The operation has been retried according to the TGExecutionRetryLimit setting but was not able to be written to the target and the operation was discarded. Correct the problem and remirror the files.

SCOM alert—Enabled

4155:   The service was unable to complete a file system operation in the allotted time. See the log files for error conditions. After correcting the problem, remirror or perform a verification with remirror to synchronize the changes.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Correct the file system error and then remirror or perform a verification with remirror to synchronize the changes.

SCOM alert—Enabled

4200:   In band task %1 submitted from %2 by %3 at %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4201:   In band task %1 discarded (submitted from %2 by %3 at %4)

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—A task may be discarded in the following scenarios: all connections to a target are manually disconnected, replication is stopped for all connections to a target, or an auto-disconnect occurs. If one of these scenarios did not cause the task to be discarded, contact technical support.

SCOM alert—Enabled

4202:   Running %1 in band script: %2 (task %3 submitted from %4 by %5 at %6)

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4203:   Completed run of in band script: %1 (exit code %2)

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4204:   Error running in band script: %1

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Review the task and its associated script(s) for syntax errors.

SCOM alert—Enabled

4205:   Timeout (%1 seconds) running in band script: %2

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—The timeout specified for the script to complete has expired. Normal processing will continue. You may need to manually terminate the script if it will never complete

SCOM alert—Enabled

4206:   Run timeout disabled for in band script: %1

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—The timeout period was set to zero (0). Double-Take will not wait for the script to complete before continuing. No action is required.

SCOM alert—Enabled

4207:   In band scripts disabled by server - no attempt will be made to run %1

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Enable task command processing.

SCOM alert—Enabled

4300:   A connection request was received on the target before the persistent target paths could be loaded.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—You may need to stop and restart your job.

SCOM alert—Enabled

4301:   Unable to block target paths, the driver is unavailable.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—If you need to block your target paths, contact technical support.

SCOM alert—Enabled

4302:   Target Path %1 has been successfully blocked

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4303:   Blocking of target path: %1 failed. Error Code: %2

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—If you need to block your target paths, contact technical support.

SCOM alert—Enabled

4304:   Target Path %1 has been successfully unblocked

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

4305:   Unblocking of target path: %1 failed. Error Code: %2

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—If you need to unblock your target paths, contact technical support.

SCOM alert—Enabled

4306:   Target paths for source %1 (%2) Connection id: %3 are already blocked

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—No action required.

SCOM alert—Enabled

4307:   Target paths for source %1 (%2) Connection id: %3 are already unblocked

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—No action required.

SCOM alert—Disabled

4308:   Error loading target paths for blocking, registry key %1 has been corrupted.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—If you need to block your target paths, contact technical support.

SCOM alert—Enabled

4400:   Failed to create snapshot set for source %1 (%2) Connection ID: %3. Error: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—The snapshot could not be created. This may be due to a lack of disk space or memory or another reason. The error code is the Microsoft VSS error. Check your VSS documentation or contact technical support.

SCOM alert—Enabled

4401:   Failed to delete automatic snapshot set for source %1 (%2) Connection ID: %3. Error: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—The automatic snapshot could not be deleted. This may be due to a lack of memory, the file does not exist, or another reason. The error code is the Microsoft Volume Shadow Copy error. Check your Volume Shadow Copy documentation or contact technical support.

SCOM alert—Enabled

4402:   Failed to delete snapshot set for source %1 (%2) Connection ID: %3. Error: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—The snapshot could not be deleted. This may be due to a lack of memory, the file does not exist, or another reason. The error code is the Microsoft Volume Shadow Copy error. Check your Volume Shadow Copy documentation or contact technical support.

SCOM alert—Enabled

4403:   A scheduled snapshot could not be created for source %1 (%2) Connection ID: %3. because the target data was in a bad state. A snapshot will automatically be created when the target data reaches a good state.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—No action required. A snapshot will automatically be created when the target data reaches a good state.

SCOM alert—Enabled

4404:   Set snapshot schedule for source %1 (%2) connection %3 to every %4 minutes. Next snapshot: %5.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4405:   Removed snapshot schedule for source %1 (%2) connection %3.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4406:   Enabled snapshot schedule for source %1 (%2) connection %3.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4407:   Disabled snapshot schedule for source %1 (%2) connection %3.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

4408:   %1 was unable to move some orphans for source %2 on connection ID %3. Check the %1 logs for further details.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Orphan files could not be moved. For example, the location could be out of disk space. Check the Double-Take log for more information.

SCOM alert—Enabled

4409:   %3 was unable to delete some orphans for source %1 on connection ID %2. Check the %3 logs for further details.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Orphan files could not be deleted. Check the Double-Take log for more information.

SCOM alert—Enabled

4410:   The registry hive dump failed with an of error: %1.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Error

User action required—Contact technical support.

SCOM alert—Enabled

4411:   The Service has detected that port %1 is being %2 by the Windows Firewall.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—The firewall port needs to be unblocked or restrictions against Double-Take removed so that Double-Take data can be transmitted.

SCOM alert—Enabled

5000:   Server Monitor service was successfully started.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5001:   Server Monitor service was successfully stopped.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5002:   Placeholders were modified to %1.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5100:   Failover completed for %1.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

5101:   IP address %1 with subnet mask %2 was added to target machine's %3 adapter.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5102:   %1 has reached a failover condition. A response from the user is required before failover can take place.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Warning

User action required—User intervention has been configured. Open the Failover Control Center and accept or decline the failover prompt.

SCOM alert—Enabled

5103:   Started adding drive shares from %1 to %2.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5104:   %1 drive shares were taken over by %2.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5105:   Attempting to run the %1 script.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5106:   The %1 script ran successfully.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5107:   Error occurred in running %1 script.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Error

User action required—Verify that the script identified exists with the proper permissions.

SCOM alert—Enabled

5108:   The source machine %1 is not responding to a ping.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Error

User action required—This occurs when all monitored IP addresses on the source machine stop responding to pings. Countdown to failover will begin at the first occurrence and will continue until the source machine responds or until failover occurs.

SCOM alert—Enabled

5109:   The public NIC on source machine %1 is not responding to a ping.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Error

User action required—The failover target did not receive an answer to its ping of the source machine. Eventually, a failover will result. Investigate possible errors (down server, network error, and so on).

SCOM alert—Enabled

5110:   The %1 script "%2" is still running.

Event log—Application

Source—Double-Take

Category—Failover

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

5200:   Failback completed for %1.

Event log—Application

Source—Double-Take

Category—Failback

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

5201:  IP address %1 was removed from target machine's %2 adapter.

Event log—Application

Source—Double-Take

Category—Failback

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

5202:  Unable to Failback properly because IP address %1 was missing a corresponding SubNet Mask.

Event log—Application

Source—Double-Take

Category—Failback

Type or Level—Error

User action required—Contact technical support.

SCOM alert—Enabled

5300:   The following IP address was added to target's monitoring list: %1

Event log—Application

Source—Double-Take

Category—Monitoring

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5301:   The following IP address was removed from target's monitoring list: %1

Event log—Application

Source—Double-Take

Category—Monitoring

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5302:   Drive share information for %1 has been updated on the target machine.

Event log—Application

Source—Double-Take

Category—Monitoring

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5303:   The application monitor script has started successfully.

Event log—Application

Source—Double-Take

Category—Monitoring

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

5304:   The application monitor script has finished successfully.

Event log—Application

Source—Double-Take

Category—Monitoring

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

5305:   The application monitor has found the %1 service stopped.

Event log—Application

Source—Double-Take

Category—Monitoring

Type or Level—Warning

User action required—Application Manager will attempt to restart the service.

SCOM alert—Enabled

5306:   The application monitor has restarted the %1 service.

Event log—Application

Source—Double-Take

Category—Monitoring

Type or Level—Warning

User action required—No action required.

SCOM alert—Enabled

5307:   The application monitor cannot contact the server %1.

Event log—Application

Source—Double-Take

Category—Monitoring

Type or Level—Error

User action required—Verify the server is running. Verify available network communications with the server.

SCOM alert—Enabled

5400:   Broadcasted new MAC address %1 for IP address %2.

Event log—Application

Source—Double-Take

Category—ARP

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

5500:   Could not connect to e-mail server. Check to make sure the SMTP server %1 is available (error code: %2).

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action requiredDouble-Take could not connect to your SMTP server or the username and/or password supplied is incorrect. Verify that SMTP server is available and that you have identified it correctly in your e-mail notification configuration. Also verify that your username and password have been entered correctly.

SCOM alert—Enabled

5501:   E-mail notification could not be enabled (error code: %1).

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—This alert occurs if there is an unexpected error enabling e-mail notification during service startup. Check to see if any other errors related to e-mail notification have been logged. Also, check to make sure the Windows Management Instrumentation (WMI) service is enabled. If neither of these apply, contact technical support.

SCOM alert—Enabled

5502:   E-mail notification could not be initialized. Check to make sure Internet Explorer 5.0 or later is installed.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—E-mail notification no longer requires Internet Explorer 5.0 or later. If you receive this error, contact technical support.

SCOM alert—Enabled

5503:   E-mail notification could not be processed. Check to make sure the correct version of SMTPMail.DLL is registered on the system (error code: %1).

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—If you are using Double-Take 4.4.2.1 or earlier and Windows NT 4.0, e-mail notification requires Windows Management Instrumentation (WMI) to be installed. Verify that you have it installed on the Double-Take server.

SCOM alert—Enabled

5504:   Could not load LocalRS.dll (for e-mail notification).

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—This alert occurs if there is an error loading the resource DLL for the service. Typically, this is caused by a missing LocalRS.dll file. Reinstall the software, using the installation Repair option, to install a new copy of the LocalRS.dll. Contact technical support if this error persists.

SCOM alert—Enabled

5505:   E-mail could not be sent. Check e-mail settings (error code: %1).

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Verify that the e-mail server that you have identified in your e-mail notification configuration is correct.

SCOM alert—Enabled

5506:   One or more required e-mail settings have not been specified (error code: %1).

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—At a minimum, you must specify the e-mail server, the From and To addresses, and at least one type of event to include.

SCOM alert—Enabled

5507:   E-mail notification could not be initialized. Check to make sure WMI is installed and available (error code: %1).

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—If you are using Double-Take 4.4.2.1 or earlier and Windows NT 4.0, e-mail notification requires Windows Management Instrumentation (WMI) to be installed. Verify that you have it installed on the Double-Take server.

SCOM alert—Enabled

5508:   An error occurred connecting to the WMI namespace. Check to make sure the Windows Management Instrumentation service is not disabled (error code %1).

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—This alert occurs if there is an error with the Windows Management Instrumentation (WMI) service. Verify that you have it installed on the Double-Take server and that it is enabled.

SCOM alert—Enabled

5600:   Part or all of the e-mail setting %1 is not in a valid format.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Verify that the include categories and exclude ID list are identified and formatted correctly.

SCOM alert—Enabled

6000:   %1

Event log—Application

Source—Double-Take Management Service

Category—None

Type or Level—Information

User action required—This is a placeholder message for many other messages. See the specific log message for additional details.

SCOM alert—No rule defined

6001:   %1

Event log—Application

Source—Double-Take Management Service

Category—None

Type or Level—Warning

User action required—This is a placeholder message for many other messages. See the specific log message for additional details.

SCOM alert—No rule defined

6002:   %1

Event log—Application

Source—Double-Take Management Service

Category—None

Type or Level—Error

User action required—This is a placeholder message for many other messages. See the specific log message for additional details.

SCOM alert—No rule defined

6100:    The job "%1" has begun provisioning a replica for %2.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

6101:    The job "%1" has successfully completed provisioning a replica for %2.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

6102:    The job "%1" has failed to provision a replica for %2. %3

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Error

User action required—Review the additional error information to identify the problem. Correct the problem and retry the operation. Contact technical support if this event occurs again.

SCOM alert—No rule defined

6110:    The job "%1" has begun a %2 failover of the replica of %3.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

6111:    The job "%1" has successfully completed a %2 failover of the replica of %3.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

6112:    The job "%1" has encountered an error while performing a %2 failover of the replica of %3. %4

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Error

User action required—Review the additional error information to identify the problem. Correct the problem and retry the operation. Contact technical support if this event occurs again.

SCOM alert—No rule defined

6120:    The job "%1" has begun undoing the failover for the replica of %2.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

6121:    The job "%1" has successfully reattached the replica and resumed protecting %2.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

6122:    The job "%1" has encountered an error undoing the failing over for the replica of %2. %3

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Error

User action required—Review the additional error information to identify the problem. Correct the problem and retry the operation. Contact technical support if this event occurs again.

SCOM alert—No rule defined

6130:    The job "%1" has begun reversing the direction of the protection of %2.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

6131:    The job "%1" has successfully reversed the direction of the protection of %2.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

6132:    The job "%1" has encountered an error reversing the direction of the protection of %2. %3

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Error

User action required—Review the additional error information to identify the problem. Correct the problem and retry the operation. Contact technical support if this event occurs again.

SCOM alert—No rule defined

6140:    The job "%1" is being deleted.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

6141:    The job "%1" has successfully been deleted.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

6142:    The job "%1" has encountered an error while being deleted. %2

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Error

User action required—Review the additional error information to identify the problem. Correct the problem and retry the operation. Contact technical support if this event occurs again.

SCOM alert—No rule defined

6150:    The job "%1" protecting %2 has completed its mirror.

Event log—Application

Source—Double-Take Virtual Recovery Assistant

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—No rule defined

7106:   The driver was unable to get valid name information from the Filter Manager for the file %2. (Filename may be truncated.) It cannot be replicated. Please contact technical support.

Event log—System

Source—RepDrv

Category—None

Type or Level—Error

User action required—Contact technical support.

SCOM alert—No rule defined

7107:   The driver was unable to get valid name information from the Filter Manager for a file. It cannot be replicated. Please contact technical support.

Event log—System

Source—RepDrv

Category—None

Type or Level—Error

User action required—Contact technical support.

SCOM alert—No rule defined

8100:   The driver encountered an unrecoverable internal error. Contact technical support. The last Word in the Data window is the internal error code.

Event log—System

Source—RepDac

Category—None

Type or Level—Error

User action required—Contact technical support.

SCOM alert—Enabled

8192:   Driver failed to allocate Kernel memory. Replication is stopped and server must be rebooted for replication to continue. The last word in the data window is the tag of the allocation that failed.

Event log—System

Source—RepDrv, RepKap, or RepHsm

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—Enabled

8192:   Kernel memory is exhausted. Replication is stopped. This may have been caused by low system resources.

Event log—System

Source—RepDrv or RepHsm

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—Enabled

8192:   Problem loading registry parameters. The last Word in the Data Window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Warning

User action required—An error occurred attempting to load configuration settings from the registry for the RepSIS filter driver. Default values will be used.

SCOM alert—No rule defined

8193:   The driver failed to create a thread required for normal operation. This may have been caused by low system resources. Reboot your server and contact technical support if this error occurs again. The last Word in the Data window is the NT status code.

Event log—System

Source—RepDrv

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—Enabled

8193:   Failed to initialize WMI support. The last Word in the Data Window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Warning

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8194:   Volume was dismounted. This message is only a warning. If you receive this message repeatedly, contact technical support. The last Word in the Data window is the volume pFltObjects->Volume.

Event log—System

Source—RepSis

Category—None

Type or Level—Warning

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—Enabled

8196:   The maximum amount of memory for replication queuing has been reached. Replication is stopped and memory is being freed.

Event log—System

Source—RepDrv

Category—None

Type or Level—Warning

User action required—Contact technical support if this event occurs again.

SCOM alert—Enabled

8198:  The driver registry path could not be saved. The default registry path will be used.

Event log—System

Source—RepDrv, RepKap, or RepHsm

Category—None

Type or Level—Warning

User action required—No action required.

SCOM alert—Enabled

8200:   The driver failed to allocate a buffer for a file name longer than 260 characters. The file will be skipped. The last Word in the Data window is the NT status code.

Event log—System

Source—RepDrv

Category—None

Type or Level—Warning

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—Enabled

8240:   The control device %1 was not created. Communication with the deduplication service will be disabled. Contact technical support if this error occurs again. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8242:   The driver failed to register with filter manager. Reboot the server and contact technical support if this error occurs again. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Deduplicated data will not be accessible and no further candidate processing will occur. Reboot the server and contact technical support if the event occurs again.

SCOM alert—No rule defined

8243:   The driver failed to Queue a Recall. This could be due to system resource limitations. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8244:   The driver failed to Recall file %1 . The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8245:   The driver failed to Query a Recall related file %2 . This could be due to system resource limitations. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8246:   The driver failed to read from a Common Store file during recall. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8247:   The driver failed to write to a link file during recall. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8248:   The driver failed to obtain information from the reparse point of a recall candidate file. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8249:   The driver failed to open the Common Store file, recall has failed. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8250:   The driver failed to create/set stream and handle contexts during PostCreate, we cannot track the file - FATAL ERROR. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8251:   The driver failed to failed to initialize cancel safe queue. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8252:   The driver failed to failed to initialize cancel safe queue. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8253:   The driver failed to set stream context, we cannot track the file - FATAL ERROR. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8254:   The driver failed to set stream context, we cannot track the file - FATAL ERROR. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

8255:   The driver failed to attach to a mounted volume of interest. The last Word in the Data window is the NT status code.

Event log—System

Source—RepSis

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—No rule defined

9000:   The driver has failed to process a rename operation. The driver will resend the rename operation. This message is only a warning. If you receive this message repeatedly, contact technical support. The last Word in the Data window is the NT status code.

Event log—System

Source—RepKap

Category—None

Type or Level—Warning

User action required—Contact technical support if this event occurs again.

SCOM alert—Enabled

9100:   The driver encountered an error opening a file from the service. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9101:   The driver encountered an error reading from the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9102:   The driver encountered an error writing to the service output buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9103:   The driver encountered an error writing to the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9104:   The driver encountered an error querying for file security from the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9105:   The driver encountered an error querying for file security from the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9106:   The driver encountered an error writing file security data to the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9107:   The driver encountered an error querying for an allocated range from the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9108:   The driver encountered an error querying for an allocated range from the service output buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9109:   The driver encountered an error writing an allocated range to the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9110:   The driver encountered an error querying for a directory from the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9111:   The driver encountered an error querying for a directory from the service output buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9112:   The driver encountered an error writing a directory query to the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9113:   The driver encountered an error querying a stream from the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9114:   The driver encountered an error writing a stream query to the service output buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9115:   The driver encountered an error writing a stream query to the service output buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9116:   The driver has failed to close a file handle. If you receive this message repeatedly, contact technical support. The last Word in the Data window is the NT status code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Contact technical support.

SCOM alert—Enabled

9117:   The driver encountered an error querying for extended attributes from the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9118:   The driver encountered an error writing extended attributes to the service output buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9119:   The driver encountered an error writing extended attributes status to the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9120:   The driver encountered an error querying for file information from the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9121:   The driver encountered an error writing file information to the service output buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9122:   The driver encountered an error writing file information status to the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9123:   The driver encountered an error querying for fsctl information from the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9124:   The driver encountered an error writing fsctl information to the service output buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9125:   The driver encountered an error writing fsctl status to the service input buffer. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—Enabled

9126:   The driver encountered an error reading from the service input buffer, KFAI_OPEN_BY_FILE_ID. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—No rule defined

9127:   The driver encountered an error writing to the service output buffer, KFAI_OPEN_BY_FILE_ID. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—No rule defined

9128:   The driver encountered an error reading from the service input buffer, KFAI_QUERY_INFO. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—No rule defined

9129:   The driver encountered an error writing to the service output buffer, KFAI_QUERY_INFO. Check the Event Viewer Application log for additional service information or contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Check for related service messages. Contact technical support if this event occurs again.

SCOM alert—No rule defined

10000:   This message is only a placeholder warning. The last Word in the Data window is the NT status code.

Event log—System

Source—Double-Take

Category—RepHsm

Type or Level—Warning

User action required—No action required.

SCOM alert—Enabled

10000:   Connect failed to node %1 for resource %2. Adding node to reconnect list.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Error

User action required—Ensure that GeoCluster is running on all possible owners and that it can communicate on the network selected for mirroring and replication traffic. GeoCluster will try to reestablish a connection using the check unresponsive node interval specified for the resource.

SCOM alert—Enabled

10001:   Reconnect succeeded to node %1 for resource %2. Will be added as a possible owner when mirror is complete.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

10002:   Disk check failed on node %1 for resource %2. Removing as a possible owner.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Error

User action required—Ensure that GeoCluster is running on all possible owners and that it can communicate on the public network. Also ensure that the disk specified for the resource is functioning correctly on all possible owners.

SCOM alert—Enabled

10003:   Owner %1 of the quorum resource %2 couldn't access the arbitration path %3. Network may be down.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Error

User action required—Ensure that the network used to access the arbitration path is up and that the server is operational. Also ensure that the arbitration share path does exist and that the account running the cluster service has write privileges to the share path.

SCOM alert—Enabled

10004:   Failover of the group %1 is being delayed. Group will be brought online when the target queue is below the limit or the timeout has expired.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Warning

User action required—No action required.

SCOM alert—Enabled

10005:   Node %1 is taking ownership of the group %2. The group will be brought online on this node.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Information

User action required—No action required.

SCOM alert—Disabled

10006:   The cluster notification thread failed to start on node %1 for resource %2. The resource should be taken offline and brought back online.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Warning

User action required—Take the resource offline and bring it back online.

SCOM alert—Enabled

10007:   The user %1 has reverted a snapshot for the %2 resource on node %3.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Warning

User action required—No action required. The snapshot you selected will be reverted.

SCOM alert—Enabled

10008:   The user %1 has discarded queued data for the %2 resource on node %3.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Warning

User action required—No action required. The queue you selected will be discarded.

SCOM alert—Enabled

10009:   The user %1 is verifying data for the %2 resource on node %3.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Warning

User action required—A snapshot of the current data has been taken. After you have verified the data, accept or reject the data.

SCOM alert—Enabled

10010:   The user %1 has rejected the data for the %2 resource on node %3.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Warning

User action required—No action required. Since the data was rejected, the data has been reverted to the snapshot taken when the data was selected for verification.

SCOM alert—Enabled

10011:   The user %1 has accepted the data for the %2 resource on node %3.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Warning

User action required—No action required. The current data will be used.

SCOM alert—Enabled

10012:   The GeoCluster Replicated Disk resource %1 has been set to validate its data. No data replication is occurring to the remaining nodes in the cluster. Please Accept or Reject the data by right-clicking on the resource and selecting the appropriate option.

Event log—Application

Source—Double-Take

Category—GeoCluster

Type or Level—Warning

User action required—Replication has been stopped because of the validation request. Accept or reject the data on the node by right-clicking on the resource and selecting the appropriate option.

SCOM alert—Enabled

10100:   The driver could not recall a file because it did not have a token for impersonation. The security provider service should set this token. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Contact technical support if this event occurs again.

SCOM alert—Enabled

10101:   The driver could not access the file in the archive bin, due to a failed impersonation attempt. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Contact technical support if this event occurs again.

SCOM alert—Enabled

10102:   The driver could not recall the file. The last Word in the Data window is the exception code.

Event log—System

Source—RepKap

Category—None

Type or Level—Error

User action required—Contact technical support if this event occurs again.

SCOM alert—Enabled

11000:   Service has started an archive to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

11001:   Service has completed an archive to %1 (%2) for Replication Set %3, ID: %4, %5

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

11002:   Service has started a recall from %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

11003:   Service has completed a recall from %1 (%2) for Replication Set %3, ID: %4, %5

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

11004:   Service has failed connection to the RepHSM driver. %1

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Reboot the server or manually restart the RepHSM.sys driver.

SCOM alert—Enabled

11005:   Service has aborted the archive operation.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Verify the activation code on the source and target is valid for archiving. Reboot an unlicensed server.

SCOM alert—Enabled

11006:   Service has aborted the archive recall operation.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Verify the activation code on the source and target is valid for archiving. Reboot an unlicensed server.

SCOM alert—Enabled

11007:   Verification has finished with errors. %1

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Review the verification log to correct or accept the errors.

SCOM alert—Enabled

11008:   Archive feature is not supported on volume %1

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—The source and target must be NTFS for archiving functionality.

SCOM alert—Enabled

11009:   Service has started an archive preview to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

11010:   Service has completed an archive preview to %1 (%2) for Replication Set %3, ID: %4

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled

11011:   Service has aborted the archive preview operation.

Event log—Application

Source—Double-Take

Category—Service

Type or Level—Warning

User action required—Verify the activation code on the source and target is valid for archiving. Reboot an unlicensed server.

SCOM alert—Enabled

12000:   The service has started.

Event log—Application

Source—Double-Take

Category—DTRecall

Type or Level—Information

User action required—This message refers to the Double-Take Recall service. No action required.

SCOM alert—Enabled

12001:   The service failed to start.

Event log—Application

Source—Double-Take

Category—DTRecall

Type or Level—Error

User action required—Check the user name and password for the Double-Take Recall service to ensure validity. Reinstall the software if this event occurs again.

SCOM alert—Enabled

12002:   The service has stopped.

Event log—Application

Source—Double-Take

Category—DTRecall

Type or Level—Information

User action required—This message indicates a system shutdown or the user stopped the Double-Take Recall service. No action is required.

SCOM alert—Enabled

12003:   The service failed to create a stop control event. (Error %1)

Event log—Application

Source—Double-Take

Category—DTRecall

Type or Level—Error

User action required—Restart the Double-Take Recall service. Reinstall the software if this event occurs again.

SCOM alert—Enabled

12004:   RegisterServiceCtrlHandler failed. (Error %1)

Event log—Application

Source—Double-Take

Category—DTRecall

Type or Level—Error

User action required—Restart the Double-Take Recall service. Reinstall the software if this event occurs again.

SCOM alert—Enabled

12005:   Service encountered SetServiceStatus error (Error %1)

Event log—Application

Source—Double-Take

Category—DTRecall

Type or Level—Error

User action required—Restart the Double-Take Recall service. Reinstall the software if this event occurs again.

SCOM alert—Enabled

12006:   Service could not get handle to driver for security update. (Error %1)

Event log—Application

Source—Double-Take

Category—DTRecall

Type or Level—Error

User action required—The Double-Take Recall service could not connect to the Double-Take Recall archiving driver. Reboot the server and reinstall the software if this event occurs again.

SCOM alert—Enabled

12007:   Service failed a periodic security update. (Error %1)

Event log—Application

Source—Double-Take

Category—DTRecall

Type or Level—Warning

User action required—This message refers to the Double-Take Recall service. The operation will be performed every five minutes. Reinstall the software if this event occurs after five minutes.

SCOM alert—Enabled

12288:   The driver encountered an error accessing a buffer from the service. Contact technical support. The last Word in the Data window is the exception code.

Event log—System

Source—RepDrv

Category—None

Type or Level—Error

User action required—Contact technical support.

SCOM alert—Enabled

16384:   The driver encountered an unrecoverable error. Contact technical support.

Event log—System

Source—RepDrv

Category—None

Type or Level—Error

User action required—Contact technical support.

SCOM alert—Enabled

16385:   The driver encountered an unexpected internal result. Contact technical support. The last Word in the Data window is the NT status code.

Event log—System

Source—RepDrv

Category—None

Type or Level—Error

User action required—Contact technical support.

SCOM alert—Enabled

16393:   The driver encountered an internal error. Contact technical support. The last Word in the Data window is the internal error code.

Event log—System

Source—RepDrv

Category—None

Type or Level—Error

User action required—Contact technical support.

SCOM alert—Enabled

16395:   The driver detected a memory error which may have been caused by a bad driver or faulty hardware. Contact technical support. The last Word in the Data window is the internal error code.

Event log—System

Source—RepDrv or RepHsm

Category—None

Type or Level—Error

User action required—Contact technical support.

SCOM alert—Enabled

16396:   The driver failed to create work queues for normal operation. This may have been caused by low system resources. Reboot the server and contact technical support if this error occurs again. The last Word in the Data window is the NT status code.

Event log—System

Source—RepDrv

Category—None

Type or Level—Error

User action required—Reboot the server and contact technical support if this event occurs again.

SCOM alert—Enabled

16400:   RepDrv has encountered an unexpected condition, usually caused by low kernel memory. Unless otherwise mentioned, this event has already been handled and your data remains protected. If you continue to receive these events or have further questions please contact tech support.

Event log—System

Source—RepDrv

Category—None

Type or Level—Information

User action required—No action required.

SCOM alert—Enabled